Sun-microsystems Netra CP32x0 Manual do Utilizador Página 19

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 66
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 18
Chapter 1 Overview 1-3
1.2 PICMG Standards Compliance
The ARTM-HD is fully compliant with the PICMG
®
2.0 Revision 3.1 specification.
1.2.1 Maximum Power Dissipation
The maximum power dissipation is 25 Watts.
1.2.2 Airflow Cooling Requirements
TABLE 1-1 lists the airflow cooling requirements based on a maximum power of 25W,
which is the only power level available on this ARTM-HD.
TABLE 1-1 Airflow Cooling Requirements
Meters Cubed Per Minute (M
3
/min) Feet Cubed Per Minute (CFM)
25 28 40 55 25 28 40 55
0.07 0.07 0.14 0.14 2.5 2.5 5 5
Vista de página 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 ... 65 66

Comentários a estes Manuais

Sem comentários