Sun-microsystems 6900 Manual do Utilizador Página 135

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 134
Chapter 9 Troubleshooting Virtualization Engine Devices 115
Sun Proprietary/Confidential: Internal Use Only
Note The Serial Loop IntraConnect (SLIC) daemon must be running for the
svstat(1M) -d v1 command to work.
Translating Host-Device Names
You can translate host-device names to VLUN, disk pool, and physical Sun StorEdge
T3+ array LUNs.
The luxadm output for a host device, shown in
CODE EXAMPLE 9-2, does not include
the unique VLUN serial number that is needed to identify this LUN. The procedure
to obtain the VLUN serial number is detailed next.
CODE EXAMPLE 9-2 luxadm Output for a Host Device
# /usr/sbin/luxadm display /dev/rdsk/c4t2B00006022004186d0s2
DEVICE PROPERTIES for disk: /dev/rdsk/c4t2B00006022004186d0s2
Status(Port A): O.K.
Vendor: SUN
Product ID: SESS01
WWN(Node): 2a00006022004186
WWN(Port A): 2b00006022004186
Revision: 080E
Serial Num: Unsupported
Unformatted capacity: 56320.000 MBytes
Write Cache: Enabled
Read Cache: Enabled
Minimum prefetch: 0x0
Maximum prefetch: 0x0
Device Type: Disk device
Path(s):
/dev/rdsk/c4t2B00006022004186d0s2
/devices/pci@1f,4000/pci@2/SUNW,qlc@5/fp@0,0/
ssd@w2b00006022004186,0:c,raw
Vista de página 134
1 2 ... 130 131 132 133 134 135 136 137 138 139 140 ... 203 204

Comentários a estes Manuais

Sem comentários