134 Sun StorEdge 3900 and 6900 Series 2.0 Troubleshooting Guide • March 2003
Sun Proprietary/Confidential: Internal Use Only
oob.slicd Comm_
Lost
Down The virtualization engine
failed to execute slicd
command.
1. Check the status of the slicd
daemon.
2. Check the power on the
virtualization engine.
3. Make sure the virtualization
engine is booted correctly.
4. Verify that the TCP/IP
settings on the virtualization
engine are correct.
5. Check the T3 message log for
failover conditions in the Sun
StorEdge T3+ array.
6. Replace the virtualization
engine, if necessary.
oob.
command
Comm_
Lost
Down Invalid command or slicd
daemon problem.
1. Check the status of the slicd
daemon.
2. Check the power on the
virtualization engine.
3. Make sure the virtualization
engine is booted correctly.
4. Verify that the TCP/IP
settings on the virtualization
engine are correct.
5. Check the T3 message log for
failover conditions in the Sun
StorEdge T3+ array.
6. Replace the virtualization
engine, if necessary.
TABLE 9-5 Storage Automated Diagnostic Environment Event Grid for Virtualization Engine (Continued)
Component
EventType Severity Information
Required
Action